Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-33436482

RESUMO

BACKGROUND AND AIMS: Digestive endoscopy is considered a high-risk procedure for COVID-19. Recommendations have been made for its practice during the pandemic. This study was conducted to determine adherence to recommendations for endoscopy practice during the COVID-19 pandemic in Latin America (LA). METHODS: A survey was conducted of endoscopists from LA consisting of 43 questions for the evaluation of four items: general and sociodemographic features, and preprocedure, intraprocedure and postprocedure aspects. RESULTS: A response was obtained from 338 endoscopists (response rate 34.5%) across 15 countries in LA. In preprocedure aspects (hand washing, use of face masks for patients, respiratory triage area, training for the placement/removal of personal protective equipment (PPE) and availability of specific area for the placement/removal of PPE), there was adherence in <75%. Regarding postprocedure aspects, 77% (261/338) had reused PPE, mainly the N95 respirator or higher, and this was with a standardised decontamination procedure only in 32% (108/338) of the time. Postprocedure room decontamination was carried out by 47% on >75% of occasions. In relationship to intraprocedure aspects (knowledge of risk and type of endoscopic procedures, use of PPE, airway management in patients and infrastructure), there was adherence in >75% for all the parameters and 78% of endoscopists only performed emergencies or time-sensitive procedures. CONCLUSIONS: Adherence to the recommendations for endoscopy practice during the COVID-19 pandemic is adequate in the intraprocedure aspect. However, it is deficient in the preprocedure and postprocedure aspects.


Assuntos
COVID-19 , Endoscopia Gastrointestinal , Fidelidade a Diretrizes , Guias de Prática Clínica como Assunto , Adulto , COVID-19/epidemiologia , COVID-19/prevenção & controle , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Controle de Infecções/métodos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , América Latina/epidemiologia , Masculino , Pessoa de Meia-Idade , Pandemias , Equipamento de Proteção Individual , Estudos Prospectivos , Fatores de Risco , SARS-CoV-2
2.
Dig Dis ; 39(3): 211-216, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33011721

RESUMO

INTRODUCTION: Capsule endoscopy (CE) is the first-line tool for diagnosis of small bowel bleeding. There are some studies that have compared different types of CE. OMOM CE is one of the newest in the market and has not been compared with other types of CE. The objective of this study was to compare the diagnostic yield of the Pillcam SB3 and OMOM CE in small bowel bleeding. MATERIALS AND METHODS: This is a prospective, comparative, randomized, and blinded study. Patients with suspected small bowel bleeding were included. All the patients were given both types of CE in random order. Diagnostic yield and functionality between the 2 types of CE were analyzed. RESULTS: We included 44 patients, 54.5% were female with a median age of 63.5 years. Battery time was significantly longer with SB3 (816.5 vs. 700.5 min, p < 0.001), and the download time was shorter with OMOM (33 vs. 132 min, p < 0.001). Both CEs presented 1 failure. The cause of the bleeding was identified in 39 SB3 (88.6%) and in 34 OMOM CE (77.3%) (p = 0.256). P2 lesions were observed in 32 SB3 (72.7%) and in 29 OMOM CE (65.9%) (p = 0.784). The agreement between both CEs for P2 lesions was moderate (κ = 0.628). CONCLUSIONS: Pillcam SB3 and OMOM devices are safe procedures and have a similar diagnostic yield. Significant differences were observed in the battery life and download time with both CEs.


Assuntos
Endoscopia por Cápsula , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/diagnóstico , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Idoso , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
3.
BMC Gastroenterol ; 20(1): 132, 2020 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-32370759

RESUMO

BACKGROUND: Third-space endoscopy is a novel, safe, and effective method for treating different gastrointestinal conditions. However, several failed endoscopic procedures are attributed to incomplete myotomy. Lighting devices are used to prevent organic injuries. We aimed to investigate the feasibility of using a hand-made LED-probe (LP) in third-space procedures. METHODS: This prospective study was conducted in a tertiary-care center in Mexico between December 2016 and January 2019. We included peroral endoscopic myotomy (POEM) and gastric peroral endoscopic myotomy(G-POEM) procedures. Pseudoachalasia, peptic ulcer, normal gastric emptying scintigraphy (GES) and prepyloric tumors were excluded. LP was used to guide or confirm procedures. Clinical and procedural characteristics were recorded and analyzed. RESULTS: Seventy third-space procedures were included (42POEM,28G-POEM), with an average patient age of 46.7 ± 14.3 and 43.7 ± 10.1 years, respectively. For the POEM and G-POEM groups, respectively, 18/42(42.9%) and 13/28(46.7%) patients were males; median procedure times were 50 (interquartile range [IQR]: 38-71) and 60(IQR: 48-77) min, median LP placement times were 5(IQR: 4-6) and 6(IQR: 5-7) min, mild adverse events occurred in 4(9.4%) and 4(14.2%) of cases, and clinical success at 6 months occurred in 100 and 85.7% of cases. Integrated relaxation pressure (IRP) improved from 27.3 ± 10.8 to 9.5 ± 4.1 mmHg (p < 0.001); retention percentage at 4 h also improved. LP was successfully placed and adequate myotomy confirmed including 14.2 and 17.8% of POEM and G-POEM difficult patients. CONCLUSIONS: Using an LP is promising and allows guiding during third-space procedures either for submucosal tunnel creation or myotomy confirmation, with excellent safety and efficacy in clinical practice.


Assuntos
Endoscopia do Sistema Digestório/instrumentação , Acalasia Esofágica/cirurgia , Iluminação/instrumentação , Miotomia/instrumentação , Piloromiotomia/instrumentação , Adulto , Endoscopia do Sistema Digestório/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , México , Pessoa de Meia-Idade , Boca/cirurgia , Miotomia/métodos , Estudos Prospectivos , Piloromiotomia/métodos , Centros de Atenção Terciária , Resultado do Tratamento
4.
Gastrointest Endosc ; 92(6): 1190-1201, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32343977

RESUMO

BACKGROUNDS AND AIMS: New mucosal resective and ablative endoscopic procedures based on gastric cardiac remodeling to prevent reflux have appeared. We aimed to evaluate the feasibility of a new ablative technique named antireflux ablation therapy (ARAT) for control of GERD in patients without hiatal hernia. METHODS: Patients with proton pump inhibitor (PPI)-refractory GERD without hiatal hernia underwent ARAT between January 2016 and October 2019. Gastroesophageal Reflux Disease-Health-Related Quality of Life (GERD-HRQL), upper endoscopy, 24-hour pH monitoring, and PPI use were documented at 3, 6, 12, 24, and 36 months after ARAT. RESULTS: One hundred eight patients were included (61 men [56.5%]; median age, 36.5 years; range, 18-78 years). ARAT was performed on all patients. At the 36-month evaluation, 84 patients had completed the protocol. Median ARAT time was 35.5 minutes (range, 22-51 minutes), and median circumference ablation was 300° (range, 270°-320°). No major adverse events occurred, and 14 of 108 patients (12.9%) presented with stenosis that was responsive to balloon dilation (<5 sessions). At the 3-month evaluation, the acid exposure time (AET), DeMeester score, and GERD-HRQL score had decreased from 18.8% to 2.8% (P = .001), 42.5 to 9.1 (P = .001), and 36.5 to 10 (P = .02), respectively, and these values were maintained up to 36 months. Success (AET <4%) was achieved in 89% and 72.2% at 3 and 36 months, respectively. Related factors at 36 months were as follows: pre-ARAT Hill type II (odds ratio [OR], 3.212; 95% confidence interval [CI], 1.431-5.951; P = .033), post-ARAT 3-month Hill type I (OR, 4.101; 95% CI, 1.812-9.121; P = .042), and AET <4% at 3 months (OR, 5.512; 95% CI, 1.451-7.621; P = .021). CONCLUSIONS: ARAT is a feasible, safe, and effective therapy for early and mid-term treatment of GERD in patients without a sliding hiatal hernia. However, longer follow-up evaluations and randomized comparative studies are needed to clarify its real role. (Clinical trial registration number: NCT03548298.).


Assuntos
Técnicas de Ablação , Fundoplicatura , Refluxo Gastroesofágico , Hérnia Hiatal , Técnicas de Ablação/métodos , Adolescente , Adulto , Idoso , Endoscopia Gastrointestinal , Monitoramento do pH Esofágico , Estudos de Viabilidade , Feminino , Refluxo Gastroesofágico/tratamento farmacológico , Refluxo Gastroesofágico/cirurgia , Hérnia Hiatal/tratamento farmacológico , Hérnia Hiatal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Inibidores da Bomba de Prótons/uso terapêutico , Qualidade de Vida , Resultado do Tratamento , Adulto Jovem
5.
Rev. esp. enferm. dig ; 112(4): 258-261, abr. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-187503

RESUMO

INTRODUCCIÓN: la insuflación de dióxido de carbono (CO2) durante la enteroscopia reduce el tiempo del procedimiento y los síntomas posteriores al mismo e incrementa la profundidad de inserción comparado con aire ambiente. En colonoscopia, la técnica de intercambio de agua (IA) se asocia a menor dolor en comparación con la insuflación de CO2. La técnica IA no está bien estudiada en enteroscopia. El objetivo de este estudio es comparar la seguridad y eficacia de la enteroscopia con IA y la enteroscopia con CO2. MÉTODOS: estudio prospectivo, comparativo y observacional, que incluyó enteroscopias de doble balón (EDB) que fueron aleatorizadas en dos grupos: el primero con IA y el segundo con insuflación de CO2. Los datos recopilados se evaluaron mediante análisis univariado y una regresión logística múltiple (variables con p ≤ 0.10 en análisis univariado). RESULTADOS: se incluyeron 46 EDB (23 por brazo; mediana de edad 63,5 años, 37% mujeres). No hubo diferencias estadísticas en la vía de acceso, los hallazgos, la terapéutica y las complicaciones entre grupos. Cuatro pacientes (20%) en el grupo de CO2 tuvieron eventos adversos (distensión abdominal y dolor) y uno en el grupo IA (náuseas) sin diferencia estadística. La mediana de profundidad de inserción fue mayor en el grupo de CO2 (260 cm vs. 160 cm; p = 0,048). La regresión logística múltiple mostró una diferencia estadística en la profundidad de inserción utilizando insuflación de CO2 (OR 1,009, 1,001-1,017; p = 0,034). CONCLUSIONES: las EDB con técnica de insuflación de CO2 y con IA son seguras con una mayor profundidad de inserción con CO2


No disponible


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Ciências da Saúde , Enteroscopia de Balão/métodos , Dióxido de Carbono/administração & dosagem , Hemorragia Gastrointestinal/cirurgia , Água/administração & dosagem , Enteroscopia de Balão/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Insuflação/métodos
6.
Rev Esp Enferm Dig ; 112(4): 258-261, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32122147

RESUMO

INTRODUCTION: carbon dioxide (CO2) insufflation during enteroscopy reduces procedure time and subsequent symptoms and increases the insertion depth compared with room air. In colonoscopy, the water-exchange (WE) technique is associated with less pain compared with CO2 insufflation. The WE technique is not well studied in enteroscopy. The aim of this study was to compare the efficacy and safety of enteroscopy with WE and CO2. METHODS: a prospective, comparative and observational study was performed of double balloon enteroscopies (DBE) that were randomized in two groups. The first group used WE while the second group used CO2 insufflation. The data collected was evaluated via univariate analysis and multiple logistic regression (variables with p ≤ 0.10 according to the univariate analysis). RESULTS: forty-six DBE were included; 23 in each arm. The median age of cases was 63.5 years and 37% were female. There were no statistical differences between the groups with regard to the access route, findings, therapy and complications. Four patients (20%) in the CO2 group had adverse events (abdominal distension and pain) and one in the WE group (nausea), which was not statistically significant. The median insertion depth was greater in the CO2 group; 260 cm vs 160 cm (p = 0.048). Multiple logistic regression showed a statistically significant difference in the insertion depth using CO2 insufflation (OR 1.009, 1.001-1.017; p = 0.034). CONCLUSIONS: DBE with a CO2 insufflation technique and WE are safe with a greater insertion depth with CO2.


Assuntos
Dióxido de Carbono , Insuflação , Colonoscopia , Feminino , Humanos , Insuflação/efeitos adversos , Pessoa de Meia-Idade , Estudos Prospectivos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...